Skip to Content

Big Deals  |  Get Free Shipping on Orders over $1999.00 (except motors)

 DWB Circuit Breakers:                                  (Overview & Key Features)

Compact and Flexible Design

  • The DWB series is built to save panel space with compact frames offering rated currents from 20 A up to 1,600 A, depending on the model—spanning DWB100, DWB250, DWB400, and DWB600.
  • Internal accessories (e.g. auxiliary contacts, shunt or undervoltage releases) are modular and user-installable, allowing flexibility across multiple frame sizes—especially 100, 250, and 400.

Protection & Trip Units

  • Models offer both fixed and adjustable trip unit options. Common trip types include:
    • DX: Fixed thermal + fixed magnetic
    • GA/GF/MF/MA: Generator or motor applications with adjustable trips
    • ET: For distribution/generator protection with electronic trip capabilities .
  • For UL-listed units, such as DWB160, breakers are available in Standard (80% rated, “E”) and Premium (100% rated, “H”) configurations .

High Short-Circuit Interrupting Capacity

  • The DWB line is built for high performance:
    • Some models feature interrupting capacities up to 80 kA at 380/415 V .
    • For the DWB100 series (80% rated), typical ratings are around 14 kA at 480 V (UL).
    • Premium (100% rated) versions maintain similar interrupting capacities.

Enhanced Safety & Accessibility

  • A transparent front cover allows quick inspection of internal accessories, aiding safety and maintenance.
  • Double insulation ensures live parts are isolated from the breaker’s front face (except terminals), reducing touch hazards.
  • Compact build and DIN-rail-compatible frames support quick replacement and system integration.

Broad Accessory Support

  • WEG offers a comprehensive range of compatible accessories, including:
    • Auxiliary contact blocks (BC)
    • Alarm contact blocks (AL, BCAL)
    • Shunt release (BD)
    • Undervoltage release (BS)
    • Mechanical interlocks, padlocking devices
    • Panel door rotary handles, phase barriers
    • Plus wiring terminals (lugs) included with DWB100 and standard on DWB250, DWB400, and DWB600.

Why Choose WEG DWB?

Advantage

Benefit
Compact, modular design
Saves space and supports easy customization and scaling.
Varied trip units
Tailor protection to specific needs — from fixed to adjustable.
High interrupting capacity
Reliable in high fault scenarios, with ratings up to 80 kA.
Safety-forward features
Transparent covers and double insulation enhance maintenance safety.

Extensive accessories

Wide range of field-installable add-ons for adaptability.


WEG DWB Series — Selection Guide

DWB100 for Distribution — Standard 80% Rated — Fixed Thermal & Fixed Magnetic Trip Unit

Frame: DWB100CE 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Rated Current
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
20 300 25 10 DWB100CE20-3DX
25 300 25 10 DWB100CE25-3DX
30 300 25 10 DWB100CE30-3DX
40 400 25 10 DWB100CE40-3DX
50 500 25 10 DWB100CE50-3DX
60 600 25 10 DWB100CE60-3DX
70 700 25 10 DWB100CE70-3DX
80 800 25 10 DWB100CE80-3DX
90 900 25 10 DWB100CE90-3DX
100 1000 25 10 DWB100CE100-3DX

Frame: DWB100JE 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Rated Current
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
20 300 50 14 DWB100JE20-3DX
25 300 50 14 DWB100JE25-3DX
30 300 50 14 DWB100JE30-3DX
40 400 50 14 DWB100JE40-3DX
50 500 50 14 DWB100JE50-3DX
60 600 50 14 DWB100JE60-3DX
70 700 50 14 DWB100JE70-3DX
80 800 50 14 DWB100JE80-3DX
90 900 50 14 DWB100JE90-3DX
100 1000 50 14 DWB100JE100-3DX

WEG DWB Series — Selection Guide

DWB100 for Distribution — Premium 100% Rated — Fixed Thermal & Fixed Magnetic Trip Unit

Frame: DWB100CH 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Rated Current
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
20 300 25 10 DWB100CH20-3DX
25 300 25 10 DWB100CH25-3DX
30 300 25 10 DWB100CH30-3DX
40 400 25 10 DWB100CH40-3DX
50 500 25 10 DWB100CH50-3DX
60 600 25 10 DWB100CH60-3DX
70 700 25 10 DWB100CH70-3DX
80 800 25 10 DWB100CH80-3DX
90 900 25 10 DWB100CH90-3DX
100 1000 25 10 DWB100CH100-3DX

Frame: DWB100JH 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Rated Current
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
20 300 50 14 DWB100JH20-3DX
25 300 50 14 DWB100JH25-3DX
30 300 50 14 DWB100JH30-3DX
40 400 50 14 DWB100JH40-3DX
50 500 50 14 DWB100JH50-3DX
60 600 50 14 DWB100JH60-3DX
70 700 50 14 DWB100JH70-3DX
80 800 50 14 DWB100JH80-3DX
90 900 50 14 DWB100JH90-3DX
100 1000 50 14 DWB100JH100-3DX

WEG DWB Series — Selection Guide

DWB250 for Distribution — Standard 80% Rated — Adjustable Thermal & Fixed Magnetic Trip Unit

Frame: DWB250JE 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Current Range
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
80-100 1000 50 14 DWB250JE100-3DF
100-125 1250 50 14 DWB250JE125-3DF
120-150 1500 50 14 DWB250JE150-3DF
160-200 2000 50 14 DWB250JE200-3DF
200-250 2500 50 14 DWB250JE250-3DF

Frame: DWB250PE 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Current Range
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
80-100 1000 80 35 DWB250PE100-3DF
100-125 1250 80 35 DWB250PE125-3DF
120-150 1500 80 35 DWB250PE150-3DF
160-200 2000 80 35 DWB250PE200-3DF
200-250 2500 80 35 DWB250PE250-3DF

WEG DWB Series — Selection Guide

DWB250 for Distribution — Premium 100% Rated — Adjustable Thermal & Fixed Magnetic Trip Unit

Frame: DWB250JH 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Current Range
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
80-100 1000 50 14 DWB250JH100-3DF
100-125 1250 50 14 DWB250JH125-3DF
120-150 1500 50 14 DWB250JH150-3DF
160-200 2000 50 14 DWB250JH200-3DF
200-250 2500 50 14 DWB250JH250-3DF

Frame: DWB250PH 3 Poles

Interrupting ratings shown in kiloamps (kA) at 240 VAC and 480Y/277 VAC.
Current Range
(A)
Magnetic Trip Point
(A)
Interrupting Rating 240 VAC (kA) Interrupting Rating 480Y/277 VAC (kA) Catalog Number
80-100 1000 80 35 DWB250PH100-3DF
100-125 1250 80 35 DWB250PH125-3DF
120-150 1500 80 35 DWB250PH150-3DF
160-200 2000 80 35 DWB250PH200-3DF
200-250 2500 80 35 DWB250PH250-3DF